AngioVueHD produces high-density scans with 73% more sampling points* to give you a 6x6mm scan with outstanding resolution. Now you can confidently evaluate fine vessels extending beyond the central 3x3mm region of the macula. Automatic montage (shown at right) expands the field of view even further by instantly combining macula and optic disc images for a 10x6mm widefield view.
*73% more sampling points than current AngioVue 6mm x 6mm scan
AngioVue lets you see the retinal vessels in a whole new way. Three-dimensional images are separated into individual layers of retinal vasculature to show you an unprecedented level of detail and isolate areas of interest.1
1. Spaide RF, Klancnik Jr JM, Cooney, MJ. Retinal Vascular Layers Imaged by Fluorescein Angiography and Optical Coherence Tomography Angiography. JAMA Ophthalmol. 2015;133(1):45-50. Published online October 09, 2014.
The AngioVue system is available in two configurations to meet the specific needs of your practice. AngioVue Retina is optimized for the retina practice and combines functional OCTA with the structural OCT scans the retina practice demands. The comprehensive AngioVue system includes OCTA capabilities and structural OCT for retina, optic nerve and anterior segment applications.
Trust the system that has been installed in more practices worldwide and featured in more peer-reviewed publications than any other OCTA technology. Partner with a company committed to industry-leading clinical education, technical support and product innovation.
The AngioVue Imaging System uses the proprietary SSADA algorithm to produce stunningly detailed images and to minimize scan acquisition time. Optovue's exclusive Motion Correction Technology (MCT™) reduces motion artifact to give you ultra-high resolution images, even in the choroid.
"The improved density of AngioVueHD provides the high resolution resembling that of 3x3 millimeter scans — the size we previously used to obtain the highest image quality — yet in a larger, 6x6 millimeter format. As a result, we have much greater image resolution for the 6x6 millimeter field-of-view, allowing for better assessment of pathologies characterized by large or oblique lesions. Extending the AngioVueHD to include an automatic montage in an even wider 10x6 millimeter format will assist me in understanding lesions as they arise outside the macula."
Nadia Waheed, M.D., MPH, assistant professor of Ophthalmology at Tufts Medical School and co-founder/director of the Boston Image Reading Center
Simplicity in Operation
iScan OCT offers all of the scans available on a traditional OCT with the added benefit of simplified operation. Scan acquisition is as easy as positioning the patient, choosing the scan and pushing start. iScan performs all of the focus and alignment operations while talking the patient through the entire exam. With iScan, your office staff will want to run the OCT
iScan is a tabletop system that is approximately the same size as a desktop computer, so any practice can find space for the system. iScan also features quick plug-and-play installation, making it a truly portable OCT system.
Take a new approach to protecting your patients' eye health with the iWellness Exam, available only from Optovue. This quick and easy scan gives you a detailed look at the health of your patient's retina and ganglion cell complex with robust normative comparison, to help you identify signs of disease before they may be noticeable on clinical exam. And because the iWellness scan is separate from the iScan medically-billable scans, it provides a new revenue stream for the practice.
iScan is available in two configurations to give you flexibility in incorporating OCT. iScan Essential offers the iWellness scan as well as basic retina and glaucoma scans for practices who are new to OCT technology. For practices seeking a fully-featured system, iScan Comprehensive provides iWellness along with all of the retina, optic disc and anterior segment scans available on the iVue system. The iScan Essential system can be upgraded to iScan Comprehensive at any time.
"OCT technology continues to evolve our understanding of the eye and the quality of care that we deliver to our patients. The iScan revolutionizes the way we think about OCT because of its ease of use and the speed of image acquisition. It makes OCT technology available to everyone, regardless of practice mode."
Mile Brujic, OD, FAAO
OCT Image:26,000 A-scan/secondFrame Rate:256 to 1024 A-scan/FrameDepth Resolution (in tissue):5.0 μmTraverse Resolution:15 μm (retina)Depth:2 - 2.3mm (retina)Scan Beam Wavelength:λ=840 +/- 10nmExposure Power at pupil:750 μWOCT Fundus Image (En Face)FOV:21° (H) x 21° (V)Minimum Pupil diameter:2.5mmExternal Image (Live IR) FOV:13mm x 9mmPatient InterfaceWorking Distance:22mm / 15mmMotorized Focus Range:-15D to +/- 12D
The Avanti Advantage
Avanti Widefield OCT gives you new information on structures outside the traditional 6x6 mm cube, separates the retina into distinct layers for detailed assessment, offers views of the vitreous and deep choroid, and gives you the ability to monitor change over time. With the extensive information delivered by the Avanti System, you can tailor your approach to treatment and truly personalize patient care.
Extensive Nerve Fiber Layer Analysis
Take your analysis of the nerve fiber layer to the next level with Avanti's trend analysis software, which tracks change in RNFL and GCC thickness and provides an estimate of future progression. This comprehensive analysis allows you to personalize treatment protocols and enhance your patients' understanding of their disease. New metrics, Focal Loss Volume (FLV%) and Global Loss Volume (GLV%), increase the sensitivity and specificity of the GCC analysis to help you identify suspected optic nerve head disease.
Expand the clinical utility of your OCT to address a broad range of patients in your practice. With Avanti's Cornea Advance, you can visualize and measure corneal angles, quantify corneal thickness and track change in thickness between visits. Avanti's Total Cornea Power software allows you to precisely calculate IOL powers in post-refractive surgery patients to optimize their visual outcomes and truly personalize their care.
The Avanti system is designed with the efficiency of your practice in mind. Scan patients faster with 70,000 A-scans per second, rapidly process scans with Avanti's background processing engine, and quickly identify potential problems with comprehensive, easy-to-read reports.
“Utilization of TCP provides an important and novel piece to the puzzle in obtaining accurate biometry.”
Jason Bacharach, MD - Director of Research at North Bay Eye Associates
OCT Camera70,000 A-Scan/SecondAxial Resolution5µmTransverse15µmAxial Resolution3µm DigitalA-Scan Depth~3mmTransverse2mm to 12mmScan Beam Wavelengthλ=840nmExposure Power at pupil750µW maximum